ce.

Anchors:

Work shall be secured to building

construction with anchor bolts, bent plates,
as indicated or required.

or angles

ad.
Hardware:
Contractor shall furnish and install all hardware shown or required for proper opera-

tion, including hinges, pulls, shelf supports, and
brackets, catches, etc., of types hereinafter specified.

8-09. COUNTERS AND BENCH TOPS:
Tops for counters,
benches or similar items shall be of the materials
shown, and except where otherwise noted, shall conform
to the following standards:
&.
Linoleum shall conform to Federal Specification LLL-L-367, for Jaspe type, standard grade; color
gray or as selected.
Linoleum paste shall conform

to Federal Specification 0-P-106,

except that paste

shall be waterproof.
Standard weight linoleum lining
felt shall first be cemented to the top, linoleum shall
then be cemented to the felt and joints and edges
weighted with sand sacks until paste has set.
b.

Hardboard, where called for on the drawings,

shall be hard-pressed,

structural fiber-board,

of the

thicknesses shown, and shall be in accordance with Federal Specification No. LLL-F-311, for Class B.
Material shall be bedded in waterproof paste and shall be

applied to the wooden sub-surfaces under pressure.

c.

Asbestos-cement Board

backing for metal

tops shall be of the thicknesses shown and shall com-

ply with Federal Specification No. SS-S-283 for Type

I sheets,
Sheets shall be securely nailed to bench
tops and back rails before application of metal sur-

facing.

d.

Plastic Tops

and back rails where called

for shall be mill fabricated of plywood with a glazed
surface of the weight called for.
Unless otherwise

shown, plywood backing shall be 3/4 inch thick, with

face veneer of V. G. Douglas Fir, birch or equal closegrained, non-resinous wood.
180-180 glaze shall consist

8-9