of three laminations of clear synthetic resin weigh-

ing 60 pounds per 1000 square feet, bonded to the

plywood under heat and pressure and providing a glazed

surface approximately 1/16 inch thick.

e.
Stainless Steel top and back rail surfacing shall be of the gauge called for and shall comply
with Army-Navy Specification No. AN-QQ-S-772A for
Class 2, Composition G, Physical Condition All Annealed

Temper,

Surface Condition 2B,

steel sheets, be turned

down at edges and secured with countersunk wood screws.

f. Wood Finish:
Wood finish for tops, where
so indicated, shall be Douglas Fir No. 1 Common tongued
and grooved of dimensions shown, and shall be laid with
driven fit and blind nailed with aluminum nails.

etc.,

g.
Mouldings:
Wooden nosings, cap mouldings,
shall be to the dimensions shown and of mater-

jals hereinbefore specified.
Metal edging shall be
of the designs indicated and shall be of aluminum or
stainless steel, secured with countersunk screws of
like material.
h.

Fixtures:

Counter and bench tops shall be

accurately cut and reinforced to receive the plumbing
fixtures called for.
Sinks shall be secured in place

by clamps as detailed, and finished with aluminum or
stainless steel sink frames screwed to the tops and

set in waterproof cement; or where so indicated for
shop sinks, shall be secured with wooden hangers and
finished with wooden trim mouldings sealed with waterproof mastic.
8-10.

DOORS AND DOOR FRAMES:

a.
Job-built doors, half doors and gates shall
be constructed of plywood and/or finish lumber as hereinbefore specified to the details and dimensions shown.
b,.
Stock doors shall be of the types and sizes
shown and shall be manufacturer's stock Douglas Fir

8-10