with floors and ceilings install 1/4 round mouldings. Plywood wainscots, where shown, shall be provided with cap moulding. Sliding plywood panels shall travel in rabbetted guides and be provided with wood pulls. Ply- wood for panels and finish moulding shall conform to par- agraph 8-02c, preceding. b. Fire resistant plywood panels of thicknesses noted shall be installed at walls, ceilings, and elsewhere as indicated on the drawings for the Building No. 116 on Location "A." Panels shall be installed as specified in paragraph 8-07 sub 1. Fire resistant ply- wood for panels and finish moulding shall be exterior grade Douglas Fir fire retardant treated, and shall con- form to the requirements of Navy Specification No. 51040 for Type "M," class "1," "Fire Retardant Chemicals for Lumber," 8-08. CABINETS,COUNTERS, BENCHES, ETC.: a. General Requirements: All cabinets, counters, benches, shelf units, and similar items shall be built to the designs and dimensions shown, and shall be of the materials hereinbefore specified unless otherwise noted. Dimensions shown are nominal. Contractor shall take off his own measurements and make such adjustments &@s are required by working conditions. are not shown or where so noted, Where details these items shall be constructed on the job to meet the requirements and con- ditions of use. In these instances construction methods and material shall be suitable to the use intended, shall be similar to like detailed items, and subject to the approval of the Engineer. b. Workmanship: All cabinet and case work, shelving, tables, benches, etc., shall be constructed in accordance with the best joinery practice, Work shall be housed, doweled, blocked, and glued together and nailed, screwed or bolted, as shown, Nails shall be set and screws concealed wherever possible. Miters shall be accurately made. Butt joints shall be made with approved fastenings to prevent separation. All work shall be sandpapered smooth and left in proper condition to receive painter's finish. 8-8