third points by diagonal extruded struts extending to
third rafter from end.
Sill angles shall be anchored to
the concrete floor slab by explosive driven coated steel
studs or anchor bolts;
f.

as shown or directed.

Erection:

1. Workmanship:

All work shall be rigidly

and accurately erected to tru line,

level,

plumb,

plane

and square in accordance with building manufacturer's
directions.
Rigid bents shall be assembled as completely
as practicable in a horizontal position before being
raised into position.

2.
Blocks and tackle shall be used as require
to pull framed structure into square for installation of

roofing sheets. Blocks and tackle shall be strung diagonally across structure approximately every third or fourth

frame, with ends secured by passing completely around knees

Tackle ends shall not be secured to knee straps.
3.

Sheeting:

Drift pins may be employed, but

not to the extent that elongated holes result from their

use.

All holes through sheeting shall be completely cover-

ed by washers. Contractor shall provide catwalks or planking when installing roofing sheets to avoid walking upon
roof surfaces,
g@.

Doors:

Doors as furnished by the building

manufacturer shall be of sliding or swing type, and shall
consist of extruded frames with corrugated panels riveted
to frames.
Swing doors shall have aluminum hinges and
aluminum cam type latch or cylinder locks.
Sliding door
operating hardware shall be of aluminum with lintle type
trolley tracks, intermediate rub rail and roller guides
at the sill.
Sliding doors shall be secured by padlocks.

Swing and sliding door frames shall consist of extruded

sections at jambs only.

2" x 4" blocking of suitable lengt

shall be placed at the top and bottom of door openings
between door posts to insure proper clearance before bolting posts to eave strut foundation angles.
h.

Vented Openings:

Manufacturer's standard

vented openings shall be of the shutter type unglazed.

Upper and lower shutters approximately 38 inches by 40

inches shall be provided in each 4 foot bay where vented

openings are required by design use.
Shutter panels shall
be outswinging, hinged at the top and supported each side
by collapsible shutter arms.
Shutters shall shade or close

13-4