te

sliding doors, (except padlocks) and window shutters

shall be metal building manufacturer's standard hard-

ware of approved types.

Padlocks,

special hardware,

and hardware for items not furnished by the building

manufacturer, shall be as specified in the "Carpentry
and Related Work" section of these specifications.

Cylinder locks and padlocks shall be keyed as specified
in that section.
7.

Flashings for roofs and openings shall

be building manufacturer's standard as detailed on

manufacturer's shop drawings.
Special flashings
required by building modifications shall be as specified

in the "Roofing and Sheet Metal" section.
8.

Rubber Plugs required for closing open-

ings between corrugated sheets and flat surfaces shall

be of synthetic sponge rubber of an approved type as
furnished by the building manufacturer, shall be shaped
to fit the openings, and shall, where required, be

cemented in place with waterproof cement.
ad.

Nominal Dimensions:

Buildings shall have a

nominal width of 24 feet, an eave height of 8 feet, a
ridge height to lower roof of 12 feet, and a length in

modules of 4 feet,

e. Framing:
Building shall be rigidly framed,
with bolted connections. Rigid bents consisting of wall
columns,

knee braces and rafters shall be assembled as a

unit and erected on 4 foot centers and bolted to the

longitudinal members consisting of sill angle, girts,
eave struts and purlins. Columns, knees braces and rafters
shall be bent plates; sill angles, girts, eave struts and
purlins shall be extrusions. Roofing and siding shall be
corrugated sheet bolted to the framing. Bolt holes for
structural members shall be dimpled, with bolts and nuts
provided with gaskets. Roofs shall be, in general,
double roofs, the upper roofing sheets to be attached to
Redwood walers bearing on the lower roof rafters. Walers
shall be attached to lower roof rafters by clip angles

with upper roofing attached to walers by spiral shank

nails. A curved vent cap approximately 5 feet in width
shall run longitudinally the full length of the ridge
and shall consist of roofing sheets supported on Redwood

rails and uprights at a distance of 6 inches above the
second roof.

eave struts,

End wall panels shall consist of columns,

corrugated gable sections and filler panels.

Eave struts for end walls shall be braced horizontally at

13-3

Select target paragraph3