RADIOLOGICAL CLEANUP OF ENEWETAK ATOLL
PROJECT TITLE Appitionan EncaPsuLation

SH No

LOCATION EntwetaK Atote
(Runir)
DRAWING (S) NO.
COMPUTED BY Pop
_ALM.__DATE_4 Sep 74 CHECKED BY

1

of

t

SECTION

DESIGN ANALYSIS
WALL PANELSTO BE CAST
.
IN PLACE. IN MAX 10‘ LENGTHS.
COVER PANELSTO BE 20’x20’,
3. WALL & COVER PANELS
TO BE KEYED PER
ORIGINAL DESIGN.
4. NEW WALLS TO
BUTT-JOINT
EXISTING
KEYWALLS

SHS

DATE

N

1.

EXISTING
KEYWALL

Zz

APPROX
HI wa

CAP

{

8’ MAX OR TO
CORAL-ROUGHENED
ve" REEF

PPROX

H{ WATER

ys

SECT “A

—+| |-— 20”
CONTAMINATED DEBRIS
IN CONCRETE SLURRY

NOTE: SHOULD NOT AFFECT
STRUCTURAL INTEGRITY
OF DOME!

PER ORIG. DESIGN

FIGURE 8-50. DESIGN FOR ANTECHAMBER.