2.

On-Site Analysis.

geometry

for

The samples are then transferred to an approximate 700 ¢

gamma

counting

for

24lAm,

152—u,

155Eu,

137Cs

and

OK. After gamma counting has been completed, the samples are split. One
portion shipped to EIC, Albuquerque Laboratory, and the other portion stored in
the Soil Library. The shipping box will have a packing list with EIC Laboratory
number and hard copy of gamma results with island location information. On-site

gamma sensitivity for 187Cs will be approximately 1 pCi/g. Pu/Am chemical

analysis will be done on island as laboratory load permits working to the goal of
chemical analysis of 10% of all 100-meter samples. The sample locations to be
processed for Pu/Am will be specified by the DOE/ERSP representative.

Off-Site Analysis. EIC offsite analysis will include processing coral sample for
90sr and all other Pu/Am not completed on Enewetak.

DOE/ERSP Procedure No. 15 assumes secular equilibrium of 90sr and 99Y has

been attained. The 90y is separated and used to quantify the 90sr,
Americium and plutonium analyses offsite include isolation of plutonium from
americium and electrodeposition. Tracers will be used to quantify plutonium and
americium activity based on the ratio of the tracer to isotope of interest.

A-28-3