qQnnaaig.
JOHNSTON ATOLL

PROGRAM 437

FasnNno.

TITLE

81003

Office Bunker

USER

STRUCTURE, FACILITY NO.

ADC

SCIENTIFIC STATION NO.

788

Bop

None
FOD

FUNDING
AGENCY

($000)

SSD

ENGR

PROC

CONST

.
.
Costs included in F&S No.

TOTAL

FURN

81002

COMPLETED
DESCRIPTION

The 25 x 40-ft.

steel arch bunker (Building 788) is located

adjacent to the S&I Building in the launch area. The bunker has reinforced
concrete end walls and is equipped with blast doors designed for 30 psi overpressures.

The bunker is air conditioned, hasexterior lighting and also has

a separate 140 cfm air supply and exhaust system.

DRAWINGS:

91-787- C2 thru C4
91-787- M2 and M3
91-787- El thru F4
91-787- W1, W2 and W6

81-3

(Completed in

1964. )

91-788-Al
91-788-S1 thru 53
91-788-E)

VOLI

April 1969

Select target paragraph3