pane.
JOHNSTON

ATOLL

F &S NO.

SCIENTIFIC

TITLE

01082

Optical Support Control Site

| user

STRUCTURE /FACILITY NO.

TC

- Subtask A609
SCIENTIFIC STATION NO.

None

FUNDING
AGENCY

($000)

DASA

goo

91-3-1il
ENGR

PROC

CONST

FODGO+120
TOTAL

FURN

Costs included in F&S No. 01081

RDT&E
EAO 1106
4101-61
PRIOR YEARS
ENGINEERING

Completed.

Drawings:

91-3-13-Cl and C2

91-3-13-E1

POST -GO
PROCUREMENT

To be accomplished.

CONSTRUCTION The Optical Support Control Site will consist of an Optical
Support Control Van and a Shop Van, both TC furnished. The Optical Support
Control Van will be a 8 x 30-ft. skid-mounted van, located on the northeastern
portion of the Island. Its long axis will be oriented in an east-west direction.
Fresh water at the rate of 100 gallons per day and sewage dispoal for photographic chemicals will be required for the Optical Support Control Van.
The Optical Support Control Van requires a clear line-of-sight in the sectors
listed below:

Sector from Magnetic North
330° to 30°

30° to 150°

150° to 210°

210° to 330°

Zenith Angle

90°
80°
90°
80°

A Shop Van will be located within 100-~ft. of the Optical Support Control Van,
Each van will require 17 kw of 120/208 volt, 3 phase, 60 cycle, electrical
power.

VOL I

April 1969