contacting flat surfaces shall be closed by shaped

sponge rubber plugs cemented in place prior to spraying.

Refer to "Painting" section for vapor-seal coating.
8-23.

TENT FRAMES:

a.
General Requirements:
Contractor shall
fabricate and erect at the locations shown all tent
frames shown or required for the work.
Concrete floor

sles, including anchor bolts, for personnel tents,
and concrete pliers for refreshment tent posts shall

conform to the "Concrete and Form Work" section of these
specifications.
b.

Matertals;:

1.

Iumber,

not otherwise called for,

2.

Plywood shall be "Plyshield EXT-DFPA-

3.

Rough Hardware:

conform to paragraph B-o2b.
UTILITY".

Ferrous metal items

including bolts, nuts, plates, washers, etc.,

be hot dipped galvanized.

shall

shall

Nails shall be spiral shank,

flat head, 615-T aluminum alloy or approved equal

aluminum alloy, or substitute as approved by the Engineer
4.

Sereening

where required,

shall be plastic

mesh as specified in paragraph 8-10c preceeding.
yard,

'
§,.
Canvas shall be 12.29 ounces per square
dark olive drab, cotton duck conforming to Type

III, Table II, of U. S. Army Specification No. 6-342.

Canvas for refreshment tents shall have triple sewed

seams and hems with 9/16 inch brass grommets and

washers spaced 12 inches on centers at the perimeter.

Unless otherwise shown, canvas for personnel tents will
be furnished by the Government.

c.
Workmanship: All members shall be accurately
cut and fitted, securely fixed and rigidly braced to
the true line, plane and plumb, with bolt holes accurate
ly drilled.
Splicing of members will not be permitted.

8-24.

CURTAINS:

Canvas curtains stall be provided

where indicated at Building No. 200, Location "B".

Canvas shall conform to paragraph 8-23 b. preceeding,
Seams and lengthwise hems shall be triple sewed and

8-16