CHAPTER I!, SECTION 3
STATIONS:

3486.01 through .15

DESIGN PSI:

SITE:

Yvonne

CONSTRUCTION: 7-20-58/8-2-58

USER:

sc

PURPOSE:

Sticky Pan

This station consisted of a concrete deadman
3 feet on a side set with the top 1 inch above
grade; a ditch 4 feet deep by 8 feet long; anda
10-inch-diameter log 8 feet long on the crest of
a berm 114 feet above grade 10 feet forward at

PARTICIPATION: 1 and 15
DESIGN PSI:

None

CONSTRUCTION: 7-21-58/7-30-58
Each station was a 2x2-foot plywood panel
supported on a 2x2-inch wood stake 30 inches
above grade. The wood stake was set 24 inches

into the ground.
STATIONS:

3487.01 through .61

SITE:

Yvonne

USER:

SC

PURPOSE:

Sticky Pan

PARTICIPATION: 1 and 15
DESIGN PSI:

None

CONSTRUCTION: 7-19-58/7-31-58

Stations 3487.01 through .16 were 44-inch

steel pipes set 24 inches in the ground with 30
inches above grade. The remainderof the stations

were

14-inch standard pipes 30 inches long

None

the ditch.

STATION:

6001

SITE:

How

USER:

ABMA

PURPOSE:

Rocket Firing Pad
and Tower

PARTICIPATION: None
DESIGN PSI:

8 psi

CONSTRUCTION: 10-21-57/4-9-58
An enclosed mobile tower. an auxiliary pad,
and a firing pad area comprised this station. The
tower was of bolted steel frame construction, 24

feet square and 90 feet high, covered with cor-

ugated galvanized steel roofing and siding. There

were six platform levels, each framed with steel
and covered with aluminum grating, designed
to allow the tower to be moved to enclose the
missile in a vertical position.

welded to the deck of the four barges anchored

off Site Yvonne.
STATIONS:

3488.01 through .05

SITE:

Yvonne

USER:

SC

PURPOSE:

Air Samplers

ts
Nia

\
oe

; a 5 hdSe
‘Pi es |

PARTICIPATION: 1 and 15
DESIGN PSI:

None-

CONSTRUCTION: 7-20-58/7-31-58
Each of these stations was a User-furnished
air sampler fastened to the deck of a barge

moored in the lagoon off Site Yvonne. Stations

3488.01 and .02 were located on YCV 9. Stations 3488.03, .04, and .05 were located on the
YCV barges 1415, 1416, and 1417 respectively.

Power for Stations 3488.01 and .02 was
supplied from the power panel in Station 3480.01.
STATION:

3489

SITE:

Yvonne

USER:

SC

PURPOSE:

Sled Shelter

PARTICIPATION: 1 and 15

—_
“eo,

(Neg. No. W-877-1)
Figure No. 2-64. Power Plant for
Station 6001 — How.
A platform at the 4-foot level was utilized

for access to the ladder and elevator to the upper

level platform. The plan opening in this plat-

form was 15x17 feet, and the remaining portions

were covered with grating. An extension, 5x24

feet, was provided at this level, outside the
siding, on each of two opposite sides. The extensions were used to support concrete ballast
blocks whichstabilized the tower.
Page 125

Select target paragraph3