Pour remaining sample from sottle into the 2 liter beaker, add 50
ml concentration HNO to boctle to rinse walls, add to beaker.
Rinse with water and add to sample.

Adjust pH to approximately 1 and heat sample to 80°C.

Stir.

Add to sample
Strontium carrier:

Yttrium carrier:
905, tracer:
CaCl

40 ng

40 mg

1 ml (X10,000 dpm)

O.1 M: 50 mi

Digest sample at 80°C for 30 minutes while stirring.
Adjust pH = 4.
Add 40 ml saturated oxalic acid solution and mix well.
Drop add 6 M NaOH to adjust oH = 4.

Digest (with stirring) for 30 minutes.
10.

Remove from heat, remove stirring bar,

ll.

Filter entire sample through a 2 inch Whatman 42 filter paper
mounted in filter assembly.

let settle overnight.

Wash the precipitate once with ammo-

nia wash solution.
12.

Transfer filter paper and precipitate to a 150 ml beaker.
125°C in a muffle furnace.

Dry at

Slowly raise the temperature (over an

eight hour period) to a maximum of 500°C.

Continue heating at

500°C overnight.

13.

Cool the sample and add small volumes of concentrated HNO.
rate slowly to dryness.

Evapo-

Dissolve residue in 60 ml of 0.08 N HCl.

Adjust pH = 1.

23