After Shot 1 the concentration of the Yersene in the aqueous
phase was changed to 1.75 per cent. The concentration of the reservoir
solution was also changed to 10.7 per cent Aerosol OT and h.7 per cent
Yersene,

A hand-controlled gate valve was located 9 1/4 in. above the

bottom of the cone so that the aqueous phase could be easily drawn off.

A quick-opening valve was located at the apex of the cone so that the
solid material could be drawn off with the organic phase,
An evaluation of the collector operation is given in Appendix
D.
3.2.2

Intermittent Fallout Collector

This instrument consists of a series of 2h trays which are exposed in turn to the fallout for any arbitrary period of time from 1 te
30 ming It was used in this project for the investigation of variations
in radiochemical composition with time. A complete description can be

found in the report of Project 2.5b, 10/
3.23

Laboratory Trailer
Analytical work at the test site was carried out primarily in

the laboratory trailer, Radiac Sec AN/MDQ-1, obtained from the Signal

Corps, which was set up on Parry Island, Eniwetok Atoll.

tion is given in TM-11-5537.

3.2.4

A descrip-

Station Layout
Two-phase collectors were located as shown in Table 3,1.
TABLE 3.1 - Station Locations

Islands

Distance from Ground Zero (ft)

Shot I _[

“BiMInt Atoll
How

:

Nan

Victor

97,730

122,230

62,500

Yoke

54,470

Bravo

u?, 70

Fox

Oboe
Tare
Eniwetok Atoll

50,600

Stot 3]

shot &

69,280

28,430

43,190

59,520

83,660
77,800

Mack

47,700

Janet
Mary

14,400
28,800

Project 6.5 Barge

35,000

19