-16- is not apparent, The amount of iodine secreted by the thyroid was calculated to be 76 ugm/day, 61) ‘UrinaryIodine Excretion Determinations Urinary iodine excretion determinations were carried out on 28 samples, The average value of 105 ug/day (range 19,5-279 ug/day) is similar to values found in the Eastern United States, It was expected that the Marshallese values would have been somewhat higher in view of their mainly oceanic environment and available sea food, Determinations of Body Burdens of Radionuclides Gamma spectrographic analyses were carried out on 158 Rongelap people using the Hanford shadow shield type whole body counter for the first time in these surveys, This counter, along with the electronic equipment, was set up in a newly-acquired air-conditioned trailer brought to Rongelap village. The background count with this eounter was somewhat higher than that recorded from the 21 ton steel room previously used, but the 40 K and the 137 Cs peaks were easily recognized, The results of these analyses are still being processed, Preliminary results indicate that though there are a few individuals with relatively high values for 13765 (nearly twice average), in general both exposed and control groups had body burdens for this isotope about the same as was determined four years previously, In muc per kg body weight the levels were about 11.5 for females greater than 15 years of age and about 15,6 for males greater than 15 years of age, (These values are slightly greater than those obtained four years ago, but since different techniques were used, this difference would not Csi appear to be significant.) 007839 These results indicate that, as noted four years