TABLE 4.]

ACTIVITY PER UNIT AREA FOR
SKIFF STATIONS, SHOT CHEROKEE

No fallout was collected on the skiffs omitted from

the table.
Station

TABLE 4.2
I.

fissions/f2

AA
BB
cc
DD

3,094
3,094
4,459
9,885

196.6
196.6
150.3
214.2

2.5
2.5
2.8
8.7

x 10"
x 104
x 10
x 104

GG
HH
MM
vv

5,720
858
8,783
452

196.2
196.1
214.0
432.0

4.6
6.9
7.7
8.0

x
x
x
x

10%
10°
10
10°

EVALUATION OF MEASUREMENT AND DATA RELIABILITY
Instrument

Measurement

Station location, ships

Station location, skiffs
Time of arrival

—_

A
A-C
A-C

Time of arrival

1c

A-D

Time of arrival

TOAD

A

Time of peak ionization rate

Time of peak fallout arrival rate

Ic

D

Time of cessation

TR

B-D

Time of cessation

Ic

c

Tonization rate, in situ

TR

A-C

Approximate

Field Measurements and Deposition Properties

Class

A

Dip counts/min at H + br

_
TIR

TIR

Comments

£500 to 1,000 yards.

+1,000 yards.
Arbitrary selection of significant increase
above background.
Uncertainty in first tray significantly above
background; arrival uncertain within time
interval tray exposed.

Uncertain for initially low rates of field
increase; malfunctions on skiffs; clockreading difficulties.
_

Uncertain for protracted fallout duration and

sharp deposition rate peaks.
Depends on knowledge of decay rate of
residual material.
Rate plot for protracted fallout and fallout
with sharp deposition-rate peaks may continue to end of exposure period; cumulative
activity slope approaches 1.
Poor directional-energy response (Appendix
A.2); variations in calibration; poor inter-

Cc
c
N
B

Apparent ionization rate, in ocean
Apparent ionization rate, in tank
lonization rate, above sea surface
Tonization rate, in situ

SIO-P
SsIO-D
NYO-M
TB, Cutie Pie

c
N
D

Total dose
Total dose
Weight of fallout/area

TR
ESL film pack
occ

D

Fraction of device/area (Fe, U)

.

,

occ

D

Original coral-sea-water
constituents

occ

c

Fissions and fraction of

occ

D

Fiasions /area

SIO-P, dip

device/area (Mo™)

chamber agreement.
Calibration variable, mechanical difficulties.
Calibration variable, electrical difficulties.
High self-contamination observed.
Calibration for point source in calibration
direction; readings ~ 20 percent low above
extended source.
See above: Ionization rate, TIR.
Assumed + 20 percent.
Bias uncertainty (Section 4.3.2); variability
of background collections; see below: Elemental composition, fallout.
Bias uncertainty(Section 4.3.2); uncertainty

of indicator abundance in device surround-

ings; see below: Elemental composition,
fallout.
Variations in atoll, reef, and lagoon bottom
composition; see below: Elemental composition, fallout.
Bias uncertainty (Section 4.3.2); device fission

yield uncertainty.

Uncertainties in dip to fission conversion
factor, ocean backgrounds, fractionation
of radionuclides, motion of water; see above:
Apparent ionization rate, in ocean.

Select target paragraph3