tin was used. In this procedure the sample in 0.1 M oxalic acid and the eluting agents (see Table 2) were passed through a 0. 28 em? x 10 cm-column of anionic resin (Dowex 1 ) of 100-200 mesh ata flow rate of 0.2 ml/min. The fractions were collected in test tubes, and, using a gamma spectrometer, the total gamma activity and the specific radionuclides then were determined. Table 2. Summary of the eluting procedure and the radioisotopes eluted from the Dowex 1 anion-exchange resin Volume in milliliters Fraction Sample eluate Isotopes eluted 20 3b!25 pH 4.8 a-d 33 Sp 125 e-f 18 sp i2s 10 Sb !25 0.1 M oxalic acid 1M H)SO, a b-f 54 sp125; Ry106_Rp106 Distilled H,O 100 -- 12 M HCL 100. Ru106_Ry 106 Resin -- Sb }25. zr®5-Np?5 The presence of Sb}? 5 in the sample was verified by analyzing the anion fraction with a standard radiochemical precipitation procedure. The SbS, precipitate obtained in this separation was dried and analyzed