distance of sample from test site.

For stations nearest the

test site, values for the post test samples were several hundre
d
times greater than for the pre-test samples.

Since the counts

of “Fe(0H)3 scavenge” and "Ca-Sr oxalate" do not equal the
count of “whole sample" evidently all of the radioactive
materials were not removed by these processes.
A rain water sample was colleeted 33 hours after the
Mike shot in the lagoon off Eniwetok Island.

A 4%50-ce sample

was evaporated and counted on November 4, 87 hours after Mike,
using a Victoreen survey meter with a one-inch end window

tube,

window thickness 1.8 mg/cm“.

The maximum count vas

10,000 per minute.
4.2

Plankton

The plankton nets were 4+ meter in diameter and 2 meters
long.

The anterior section was cylindrical, the posterior

section conical with a detachable net end.

The plankton tows

were made in pairs, at the surface and during daylight hours.

One net of each

pair was constructed with No. 6 silk (74

meshes per inch) and the other of No. 12 silk (173 meshes per

inch).

Towing time was usually one hour and the distance

towed was about 14 miles.

Catches of plankton were small.

Exclusive of jelly fish the greatest volume of plankton in a

one-hour tow was 28 cc.

This value was obtained by decanting

and measuring the preservative and then subtracting this

amount from the volume of preservative and plankton.
A gross examination of the types of organisms present
~

2D ~

Select target paragraph3