j

AIR SAMPLER CHARACTERISTICS

FILTER MATERIAL: "Delbag" polystyrene Absolute filter (99.8% collection
efficiency for . 3p).

HIGH VOLUME: 2 units used simultaneously at two sites.

Q = 1800 m3/hr.

Unattended endurance = 36 hrs.
Q total = 65,000 m3.
Filter Area = 1.25 m2,

LOW VOLUME: 5 units: two site pairs; Palumbo Shipboard.
Q- 8m3/hr.
Unattended endurance = 5 days.

Q = 1000 m3/5 days.

Filter Area = 0.032 m2,
CASCADE IMPACTORS:

2 units used at two sites.

Q = 34 m3/hr.

Unattended endurance = 5 days.

Q = 4100 m3/5 days.

5 fiberglass filters each with particle
separations:

> 7p; 3.3—7. 0p; 2.0—3. 3p;

1.1—2,0p; .O1—1. lp.

RECORDING WEATHER STATIONS: Portable station at Yvonne and Coast Guard at ENT.