For thia reason it makee it

particularly difficult to use a counting
inetrument at a pulse accelerator site,

The average gamma rate level at
such a site may be small, the average level

may be rather emall and a typical example
of an electron synchroton, the duty cycle

may run to 400 microseconds per second and
this means to get the instantaneous dose
rate one has to multiply the average dose

rate by at least 2500,

Our final consideration & that

had we a perfect flux measuring device

with a perfectly flat response to all neu-

trom energy, nonetheless we shall have to

know something about the neutron energy

spectron in order to make an estimate of
the permissible flux in a particularregion,

At precent our spectro knowledge
depends on knowing the maximum originals
energy of the neutrons in performing paraffine and cadmium absorption measurements
with a free detector.

However, should the neutron be pro-~

duced to say 400 MEV or something on this

order, then our information is hardly reliable,

9