oe

hy.

Sate Re eee

JOHNSTON ATOLL
F @S NO.

81008

USER

ADC
FUNDING
AGENCY

TITLE

gs.

Missile Launch Facilities

eae

geste ”

STRYREPRE/FACILITY NO.

SCIENTIFIC STATION NO.

“SADO and 794

91-7-18 and 91-7-19

a ,
($000)

ENGR

PROC

CONST

TOTAL

SsD

PRE-GO
Prior Cost

6.8

60.5

67.3

ITF-8
CRO 68-9}

PRE-GO
FY-69

7.0

89.1

96.1

AEC

PRE-GO

FY-69

57.0

TOTAL

70.8

FY-70

PRIOR YEARS

57.0

Boo
Foo

4

FURN

sg

.

|

275.0

275.0

wk

424.6

495. 4*

a

*

Roy, —

aa

ENGINEERING Completed.

Drawings:

91-6100-S13
91-6100-M1L thru M7
91-6200-El thru E5

91-6200A-E] and E2

JS 91-6100-S103 and $104
JS 91-6100-M100, M101 and M112
JS 91-6100-E100 thru £102

PROCUREMENT Completed.
ain

os

CONSTRUCTION The two Thor Missile Launch Facilities are located within the
ADC secured (fenced in}igrea on the north central shore of the island. The
launch facilitiee:
Mid for the Thor Type DSV-2J missile with a revetted
trailer and eqyiiee er

ter to either side and a roll-back missile shelter.

Me suel tanks are in open pits at opposite sides of the launch pads.

Wiexected, is adequately lighted for night television viewing
and photographiig@. Other ageas, suchas the LOX tank and the LOX and fuel lines,
are lighted for television surveillance. Each launch facility is equipped with a

Firex system, supplied with approximately 40,000 gallons of stored freshwater

plus an unlimited back up of saltwater pumped directly from the adjacent lagoon.
Signal cables to the launch facilities are carried in above ground cable trays,

where practicable, and in cable troughs or trenches under the road network.
All traffic in and out of the secured area passes through the security gates at the
Guardhouse (Building 786). Security lighting is provided at the launch facilities
81-8