LE-S
SUBMARINE CABLE TESTS (Continued)
Instruments:
(1)
(2)
Temperature _
Megger
Air (Average)
Wheatstone Bridge
DATE
OF TEST
CD
S40Or
Water (Average
COPPER RESISTANCE
PER PAIR
AB.
.
(OHMS )
EF
GH
INSULATION RESISTANCE
TO GROUND PER PAIR
JK
AB
cD
(MEGOHMS)
EF
GH
F
INSULATION RESISTANCE
TO ALL CONDUCTORS PER PAIR
JK
AB
cD
(MEGOEMS)
EF
GH
JK
.320
.320
.270
.280~
.300
.300
.200
.230
.200
2300)
.200
.230
.171
«300s
.200
.320
«. 300
-
-*
.-
CABLE NO. 0-208 (Type 115-P, 10-Conductor, Runit to Coral Head, 44,000 ft, laid 2-20-48)
3-16-48
10-9-48
2-10-k9
41-13-49
5-30-50
2-27-51
200.4 203.4 203.8 203.9 203.4
2.8
1.1
202.3 205.3 205.7 205.7 205.3 1.000 .450
200.5 203.5 203.9 203.9 203.5 1.000 .500
201.7 204.7 205.2 205.3 001.2 .850 .380
20h
204
205
205
204 .700 .400
All Pairs Open Near Station #69 at Runit
0.75
.300
.300
.280
.300
0.67
.250
.300
.210
.200
O.77
.250
.400
.250
.250
.900
.800
.400
.400
CABLE NO. 0-211 (Type 115-P, 10-Conductor, Runit to Parry, 61,000 ft, laid 1-10-48)
3-16-48
10-9-48
2-8-h9o
10-29-k9
5-26-50
2-27-51
284.8
287.1
285.0
286.9
286
292
285.5
288.0
286.2
287.7
287
«293.
286.0
288.6
286.2
288.2
287
294)
285.9
288.3
286.1
287.9
287
gk)
286.5
2.5 0.70 0.37 0.43 0.38 289.3 .700 .300 .175 .175 .160 286.7 1.000 .500 .300 .300 .300 1.000 .400
288.7 .800 .320 .200 .200 .180 .850 .340
288 .350 .306 .200 .171 .350 .306 .222
2gk 6700). KO0—(—«w3300—«=#3300'=—'s'«w 300s«w T00—s«=#“7HOO.
CABLE NO. 0-212 (Type 115-P, 10-Conductor, Runit to Parry, 58,000 ft, laid 1-13-48)
3-16-48
10-9-48
2-8-h9g
10-28-49
5-26-50
2-27-51
278.1 278.2 280.0 280.2 279.3
2.2 0.29 0.39 0.28 0.29 -
280.5 280.6 282.5 282.7 281.8 1.200
278.2 278.3 280.0 280.3 279.6 1.000
280.2 280.3 282.1 282.3 281.4 .800
279
279
«#281
281
281 .559
285
295
287
28
28 .500
.700 0.175
.200 .150
.125 .115
.120 .121
.200 .200
.090
.150
.100
1.100
.150
.090 .125 1.100
.090 .280
.086 .597
.150 .500
-
.250
.180
.150
.200
.250
.125
.111
.200
.230
.110
.111
.150
.220
.105
.086
.200