b.
Substitutions:
Substitutions of sections,
or modifications of details, or both, shall be made
only when approved.
ec.
Responsibility for Errors:
The Contractor
alone shall be responsible for all errors of fabrication
and for the correct fitting of the structural members
shown un the shop drawings.

d. Templetes:
Templates shall be furnished where
called for on the drawings.
The Engineer shall furnish
instructions for the setting of anchors and bearing
plates and shall ascertain that the ittems are properly

set during the progress of the work.

6-05. MATERIALS: Structural steel shall conform to the
requirements of A.S.T.M. Designation A 7-46. All other

materiels shall conform to applicable specifications as
set forth in Chapter 27 of the Uniform-.Building Code.
6-06.

INSPECTION AND TESTS:

The material to be furnish-

ed under this specification shall be subject to inspectior
and tests in the mill,

shop and field by inspectors

authorized by the Engineer.

However, inspection in the

mill or shop shall not relieve the Contractor of his
responsibility to furnish satisfactory materials, and

the Engineer reserves the right to reject any material

at any time before final acceptance when, in the
opinion of the Engineer, the materials and workmanship
do not conform to the specification requirements.

6-07.

DESIGN:

The design of members and connections

for any portions of the

structure not indicated in the

design drawings shall conform to the requirements of

the current issue of the Specification for the Design,

Fabrication, and Erection of Structural Steel for
Buildings of the American Institute of Steel Construction
Shop Drawings showing such designs shall be comparable
in extent of information and detail to those issued
by the Engineer.
6-08.

WORKMANSHIP:

@.
Connections: All connections shall be as
shown on the drawings.
When details are not shown,

the connections shall conform to the requirements for

series B, A.I.S.C. standard connections.
One-sided
or other types of eccentric connections shall not be
permitted except when shown in detail on the drawings.

6-2