APPENDIX 1 nergy Absorptio; CALCULATION OF IONIZATION CHAMBER RESPONSE ftormly es Gamma Ray Response kt _-576_ Wair = ea ) Ceo (=) (me) ve (ur/hr) . G.6 x 10719 amperes 10n pair (F x G) . 1on pairs am Te} [Lr r ‘ E rv where V = active volume of chamber P = filling pressure (5.58 x 102 em), (59.2 atmospheres at stp.), F = effective attenuation due to wall of text), (.90, see pg. G = enhancement due to steel-argon boundary (1.01), 24 be/o)da = the average ratio of mass energy absorption e/°)air coefficients over the range 0.3 - 2.5 MeV (.91), and a/aiy) = the ratio of gas densities and W, = 26.4). (1.38), Wai; = 33.8 Then k, = (.91) (1. 38)(333.8) 3-8 (5, 58x10) (59. 2) (.576) (1. 6x10719) ul (.90) (1.01) 4.45 x 10-14 amperes/ (ur/hr). The estimated uncertainty in this calculated value is 5-10%. Cosmic Ray Response ko = RVP .576(ion pairs/em?-sec) ur/hr 1.6 x 10719 amperes (F x G) ion pairs - 33 -