CHAPTER 7

EXPOSURE GEOMETRY EFFECTS
7el

DISCUSSICN

In clinical and laboratery exposures, the radiation flux usually
follows a narrow beam or at least a point-source "divergent" geometry,
when an air-dose is used to specify the exposure conditions for a
thick target, it is generally measured at the point subsequently oc~
cupied by the center of the proximal surface of the patient or experimental animal with respect to the source, For field exposures such as
occurred on the islands, the radiation source is not a poir.t and the
exposure geometry is "diffuse" rather than "diver;ent,"

when a cloud or a large planar area is the source, all surfaces
of the irradiated individual are "proximal," in the sense that the air-

dose measured anywhere in the space subsequently occupied by the individual is the same, Itis this airedcse which is measured ty a field
instrument; it dees not bear the same relationship to the skin dose
and depth dose as does the air-dose measured in a point source geometry. If a bilateral exposure is made in the laboratory, one-half the
dose is usually given with one side of the individual facing the source
and one-half with the other,
This is a closer approach to the fiela
geometry, But, if the air-dose has teen measured at the center of the

proxinal surface as above, it is still not related to the depth dose
in the same way as is the fielc air-dese,

The doses received by the individuals on the islands were from

both the cloud itself and the fallout deposited on the ground,

It is

believed likely, as discussed in Chapter 6, that the cloud dose was

only a small part of the total dose and that the dose frcem the plane

ground source contributed the major portion.

This ccrresponds to the

assumption of early maximum activity and short effective fallout time

which was made in Chapter 6 for the maximum dose case,

Alternatively,

if a long fallout actually occurred, the source would have remained a

cloud longer and the cloud volume, rather than the surface ¢cistribution, would have accounted for more of the total dose,

In either case,

it would appear that the midline dose, rather than the cose measured

in air, would be the better common parameter in terms of which to pre-

@ict biological effect, Since most existing data tacitly assumes narrow beam geometry, this distinction becomes important in relating
field air-doses and their consequences to known clinical or experimen-

tal results (Feferences 11, 12).

O32

C18

Oo

Select target paragraph3