BRAVO, the maximum intensity below deck on any ship due to contaminated saltwater systems was measured on the exterior of an auxilary condenser on the CURTISS (Reference 10). This reading was 30 mR/hr, but Reference 10 states that "the average intensity in the engineering spaces where this condenser was located was only about 2 milliroentgens per hour" (48 mR/day). The ship contamination model predicts an average intensity below of 25 mR/day for the CURTISS (Table 2-6, March 6) which is consistent with a maximum reading of 48 mR/day. It was calculated (Reference 6) that engineering spaces in the vicinity of saltwater piping systems would have intensities approximately 1.5 times the average below deck intensity; hence, the measured maximum on the CURTISS appears to support the ship contamination model. 66