0018933

2,6 DATA REDUCTION
The analytical results were computed in the normal manner for the
elemental analyses done for the project,

However, the first, and more

time-consuming phases of the data reduction were carried out on the IB M
650 computer at UCRL, Livermore,

The radiochemical data were manually

transcribed to IBM cards in the proper form for use by the computer, which
was coded to apply a least-squares fit to the decay data and to make corrections for chemical yield, radioactive decay and the aliquot of the sample

used,

The output of the computer gave the counting rates for the individual

radionuclides at zero time of the shots,

Further computation was performed by hand to obtain the number of
fissions, product-to-fission ratios or R-values,

Determinetion of the

R-values, defined in Section 1.2.1, required calibration values on fission
products from the thermal neutron fission of u235,

When these were not

available, or only recently obteired, comparison enalyses between LASL
'

and NRDL provided the necessary factors,

Select target paragraph3