4.2.4 Conclusions and Recameendarions Inforaation was obtained from each type of detector exposed except chemical dye dosimeters which suffered age deterioration, and gamma-dose-rate instruments at the two high stations om each shot which wre apparently below their detection thresholds when radio propagation was resumed after several tens of seconds. Most film emlsions show a marked increase in sensitivity to gamma rays of low energies (less than about 0.15 Mew), while the sensitivity of many organic fluors decreases in this region. One would, therefore, expect bare fils badges to indicate considerably higher doses if an appreciable portion of the incident gamma vere in the lower end of the spectrus. REFERENCES . 1. Malik, J. S., Summary of Information on Gamma Radiation from Atomic Weapons, 2. Minzer, R. A., Champion, K. S. W., and Pond, H. L., The ARDC Model Ataos- « La-1620, Los Alamos Scientific Laboratory, January 1954. phere, Air Force Cambridge. Research Center, 1959. 3- Cook, T. B., et al., High Alcirude Measurements, ITR-1601, Sandia Corporstion, January 1959. kh, 5. Private coumunication from C. B. Mehl, Sandia Corporation. LASL-DIR 1436, Monthly Prograa Status, Los Alamos Scientific Laboratory, March 1959. .

Select target paragraph3