Table 13.1-1 4s a summary of the data obtained in the region
prior to boost.
The indicator numbering convention lists the detector
number in the tens position and the scope number in the units position
(1 is EG&G ~ 3343, 2 is K-1421, 3 is K-1409).
The conversion from
roentgens to neutrons at the tuballoy - aluminum interface was obtained
through use of Watt's Program 5 code (LA-1984) considering all neutrons
equivalent ani taking only the uranium as the source of 0 -rays.
is the same proc-dure used by Watt).
(This
First-order least square fits to
the data were made by Goodwin (J-13) and Harper (T-1) and are listed
topether with values obtained by "G&G's graphical base-line and
difference methods,
]
The data obtained are shown in Figs 13.1-1 thru 13.1-6.
The data
shown in Fiz, 13.1-6 are probably not relevent and are shown only to
indicate dynamic range and was not the only limiting factor to explain
the loss of boost data,
The values of alpha obtainei by the least squares method versus
time obtained by the common timing system is shown in Fig. 13.1-7
together with a fit to the points.
This yield a value of dd/dt =
‘DELETED
measurement,