CANTON

F &S NO.

TITLE

USER

STRUCTURE/FACILITY NO.

21001

TC

Debris Tracking by Resonant Scattering Equipment - Subtask A606
SCIENTIFIC STATION NO,

None

BOD

108-3-1

GO+138

FOOGO+159

FUNDING
AGENCY

($000)

DASA/
RDT&E

PRE-GO
Prior Costs

EAO 1106-|}

POST-GO

4101-61

ENGR

PROC

CONST

1.5%

FURN

1.5

Estimate 12/65

TOTAL

TOTAL

1.5

8.9

8.9

8.9

10.4

PRIOR YEARS
ENGINEERING Completed.
Drawings:

108-002-C2

108-3-1-Cl

POST -GO
PROCUREMENT

To be accomplished.

CONSTRUCTION A technical operations shelter will be required to provide
office and recording instrument space. This building will be 8 x 8-ft., wood
frame construction with plywood siding, corrugated aluminum roof and erected
on aconcrete slab. It will be air conditioned and dehumidified to 50 percent
humidity. A © x 6-ft. concrete pad 18~in. thick will be constructed about 20-ft.
from the building for mounting TC furnished camera equipment. Electric power,
including back up, will be provided by two 5 kw, 120/240 volt, 60 cycle, single

phase generators. Refer to Figure A-18, Appendix A, for location. The number
of scientific personnel assigned to Subtask A606 at this location is one.

*Includes engineering costs for F&S Numbers 22001 and 24002.

21-3

VOL II

April 1969