The coefficients By were found by solution of the simultaneous equations: 8 By + 858) =m 1 N where 8, = > ; n = 1 tk n a N my, = > ok Yn» and N is the number of n = measured areas. Thedetails are not shown here but the rt results are as follows:: For He203; y = 1.3022 - 0.0154t, For Na@?; y = 0.4336 - 0.0014t, Areas were computed from the equations for each day that spectra were made and compared with the measured areas. for He@?3 The average deviation for Na? was 0,03 in 2 and 0 eee ae ee was 0.106 in’, The average percentage deviation was 2.0 per-— cent for Ne®2 end 5.4 percent for Hg?05, The probable reason for the higher deviation for Hg295 is a combination of fewer records, shorter half life (requiring progressively more sensitive count-rate scales with consequent loss in statistical accuracy during the latter part of the recording period) and higher amplifier gain requiring the use of more sensitive count-rate scales to provide peaks of adequate height. 32 a eae