UNCLASSIFIED The Green continuous-action cloud chamber has been placed in operation and calibrated. It was found suitable for measuring aerosol pares concentrations, regardless of particle size or size distribution, in the approximate range of 5 X 10+ particles/cc to 2 X 10° particles/cc, with an accuracy of 5.2% standard deviation when a total of 200 particles is counted. ORNL - 1656 ~- ELECTROSTATIC PRECIPITATOR FOR MEASURING PARTICLE-SIZE DISTRIBUTION IN AEROSOLS. Bernard G. Saunders and R. L. Quinn, 8 February 1954. ' UNC LASSIF IED (U) This report summarizes the work accomplished in developing an electrostatic precipitator for the determination of particle-size dis- under a microscope in order to determine, the size distribution. The object of this project was to develop an instrument that would operate semi- automatically by indicating the particle distribution electrically. The scheme was to collect the charge-bearing particles on a series of collector plates. Particles of each size range would fall on @ particular plate and impart charges at a measurable rate. Thus, a comparison of the beam currents would give the size vs number distribution. A precipitator designed to meet this objective has been partially built and tested. Laminar flow of the smoke in the system was obtained. Under a given condition of laminar flow, the smoke stream can be seen to bend in an are and diverge like a spectrum, as anticipated. It was hoped that the performance of the precipitator could be checked by measuring the diameters of the particles collected in various locations. Samples were collectec on the plates for a variety of operating conditions. Electron photo-micrographs were made of the particles. At this reporting, none has been obtained which is sharp enough to permit measurement. Before further progress can te made, the problem of obtaining satisfactory micrographs must be studied. ORNL - 1657 - ROTATING PRISM FOR USE WITH CLOUD CHAMBERS. Bernard G. Saunders, 15 February 1954. UNCLASSIFIED ~(U) The use of a rotating prism is indicated when one wishes to -observe moving cloud-chamber droplets and to measure their velocities. UNCLASSIFIED WNRO ee ae pe eee Devices of this sort have been constructed by other laboratories. Their operation depends on the Cepositing of particles by electrostatic means along a plate at distances corresponding to the particle size. Such devices have heretofore required that the deposited particles be counted ee tribution in smokes. :

Select target paragraph3