JOHNSTON ATOLL
F &5 NO.
01021
USER
SCIENTLEIC
TITLE
Igniter Checkout Building
STRUCTURE/FACILITY NO.
SANDIA
SCIENTIFIC STATION NO.
718
BoD
None
FOD GO+120
FUNDING
AGENCY
AEC
($000)
ENGR
PRE-GO
Prior Cost
PROC
1.6
CONST
5.5
TOTAL
FURN
7.1
POST-GO
Est.
12/68
TOTAL
0.5
2.1
5.5
19,0
19.5
19.0
26.6
PRIOR YEARS
ENGINEERING
Completed.
Drawings:
91-030-W9 and W10
PROCUREMENT Completed. The 8 x 8-ft. RF shielded structure has been
procured and is being stored at Johnston Atoll.
POST-GO
CONSTRUCTION The Igniter Checkout Building will be an 8 x 8-ft. RF
shielded structure with a double shield mesh type enclosure designed for exterior weather exposure, and will be set on a concrete slab.
The building
will be air conditioned for corrosion prevention.
A workbench and storage cabinet will be required. Lighting over the workbench will be 50-foot-candles. A 115 volt, single phase, weatherproof,
duplex receptacle will be provided at the exterior of the building adjacent to
the door. All wiring entering the shielding will be filtered. An igniter test
chamber will be fabricated for use in this building.
1-25
VOLI
April 1969