eee
JOHNSTON ATOLL
SCIENTIF
F&SNO.
TITLE
01105
Assembly Buildings
USER
STRUCTURE/FACILITY NO.
TC
FUNDING
AGENCY
Subtask A905
SCIENTIFIC STATION NO.
878 and 960
($000)
JTF -8
PRE-GO
CRO7-64
POST-GO
MILCON
-
None
ENGR
Prior Cost
BOD
PROC
7.7
FODGO+135
CONST
TOTAL
177.2
184.9
Estimate 3/65
TOTAL
FURN
0.3
7.7
177.2
184.9
0.3
COMPLETED
DESCRIPTION These two buildings (completed in 1966) are 40 x 50 x 20 1/2-ft.
high concrete block structures with steel framed built up roofs, and concrete
floors. Double sliding doors, 16 x 19-ft. high, are provided in the south wall
for monorail operations. The monorail has a 6-ton explosion proof hoist with
a minimum hook height of 15-ft. and extends to approximately 20~ft. outside of
each building.
All interior electrical installations are explosion proof. The main distribution
panel is externally mountedina weathertight enclosure. Ground clips are provided on 15-ft. centers. A central compressed air system located near Build-
ing 964 will provide 230 cfm of air at 90-100 psi.
Protective berms are provided on three sides of each building with the unprotected side facing the runway. (See F&S No. 02066.)
DRAWINGS:
91-960-Al and A2
91-960-M1 and M2
91-960-Cl
91-960-E1 and E2
91-960-S1 and S2
91-960-W1
-
1-83
VOL I