726
PELLETIER, WHIPPLE, AND WEDLICK
collectors was only a small fraction of the total activity collected. For
the sampling sites in England where the deposition velocity was 0.07
em/sec, only 7% of the total deposition was associated with dry fallout.
At the sampling site in Norway where the deposition velocity was 0.7
cm/sec, only 14% of the total deposition was associated with dry fallout.
SAMPLING AND ANALYTICAL PROCEDURES
Environmenta! Survey Around the Enrico Fermi Atomic Power Plant
There were ten rain-sampling and nine air-sampling locations used
in the environmental survey around the Fermi Reactor. Figure 1 shows
the locations of these sampling sites. The area included in this survey
is roughly 500 square miles. The terrain is relatively flat, and the
wind blows predominantly from the southwest. The Enrico Fermi Reactor was either not operating during the period covered by these mea-
DETROIT ()
ANN ARBOR(A)
witLow RuUN©
METROPOLITAN
Huron
(B) AIRPORT
River _. TRENTON
CANADA
(A) AIR
(P) PRECIPITATION
Swan Creekn
MILAN (P)
TECUMSEH
FLAT ROCK (A)
CARLTON @)
SCOFIELD @)
DUNDEE (®)
MONROE @)
LAKE ERIE
MICHIGAN
TOLEDO
(P)\ PELEE ISLAND
©
PORT CLINTON @)
Fig. 1—Sampling sites for the environmental survey around the Enrico
Fermi Atomic Power Plant.