Project 2.274 Gamma Dose Rate vs Time — P. Brown
OBJECTIVE
To measure residual gamma radiation intensity as a function of
time at land fallout stations, and to measure the initial gamma
intensity vs time for a high yield air burst,
INSTRUMENTATION
The initial gamma dose rate vs time was to be detected by
scintillator-photomultiplier detectors with time response to 10 msec,
Residual and fallout gamma intensity vs time was to be measured with
ionization chambers and associated electronics.
Station locations
Spread from Bokobyaadaa (Able) through Namu (Charlie) to Fnyu (Nan),
and on the YAG's and LST 611.
RESULTS
Usable data was not obtained for either initial or residual
radiation rates vs time.
firtre. cr?
\