40293 7

TABLE I
Factors for Converting Air Concentrations of Radioiodine
to Thyroid Dose via Inhalation*

(mrem/yrper pCi/m?)
Age

I-129

1-130

I-13)

1-132

I-133

1-134

1-135

Tyr

20.8

2.22

20.4

0.250

5.05

0.0637

1.12

4 yr

10.7

1.2]

10.6

0.135

2.59

0.0343

0.598

14 yr

«(17.5

0.880

0.0824

1.91

0.0237

0.413

Adult

36.3**

1.01

0.109

1.99

0.0273

0.471

*

8.53
10.4

Breathing rates assumed: 1-year old, 5.6 m3/d; 4-year old,
7.0 m3/d; 14-year old, 13.5 m3/d; adult, 20 m3/d. Organic and

inorganic forms of radioiodine give the same dose via inhalation.

**

Dose in first year.

Maximum dose rate after equilibrium is

reached between thyroid burden and intake rate would be 1.09
times this value.

Revised May 1976
.
To change ty and t for short half-life radioiodines per ICRP Publ. 10.