4.1.3—The Bendix Model 611 pocket dosimeter, 0 to 5 r range, was

chosen for use at the Pacific Proving Grounds ufter an extensive testing

program.

This dos{meter was found to be the most satisfactory of the sev-

eral tried as its response in the high temperature and humidity was the most

dependable. Two thousand were purchased. In general, tha dosimeters were
quite satisfactory in giving rapid information as to the dosage received by
an individual,

Many inaccuracies, however, were noted in the dosimeter read-

inga, and therefore this information was primarily used only as a guide to
how quickly the mission film badge should be processed. If Indicated by the
dosimeter reading, the mission badge would be processed immediately upon

turn-in. All dosimeters were proof-tested at LASL to a pressure equivalent
to 50,000 ft MSL, and each was tested for electrica) leakage. In general,

the proof-testing program was quite satisfactory.
was approximately 15 per cent.

The average reject rate

4.1.4—To simplify the issuance of mission badges, all personne! in

TG 7.1 and TG 7.5, and others where necessary, were issued "charge-a-plates"
similar to those used !n commercial charge-account operations. Use of these

plates eliminated filling out forms by hand, thus speeding up the issuance of
badges tremendously.
4.1.5~Following disclosure of the deficlencies tn the permanent film

badge, a vigorcus experimental program was undertaken in an effort to develop a film packet and badge holder that wouid not be susceptible to walermarking and light leaks. Various methods of packaging the film packet, such
as using a polyvinyl plastic in place of the cellulose acetate, were tried. In
addition, the film packets were dipped in ceresin wax prior to sealing in the
cellulose acetate hulder. Also, the standard film badge, complete with ace-

tate holder, was coated with various materials. The results of the experimental program indicated that the film packets that were dipped in ceresin
was before sealing in the cellulose acetate holder were most satisfactory.
The experimental program with these particular badges {s continuing at the
Eniwetok Proving Ground.

4.2

Film Processing and Record Posting
All film processing and record posting was done manually.

As a re-

sult, as many as 40 individuals were assigned to the Dosimetry and Records
Section. The manual reading and posting operations were tedious and timeconsuming, and also subject to many errors. A continuing re-check was required to ensure the greatest accuracy possible, but this was not always suc~
cessful, The master-record file for all personnei in Joint Task Force SEVEN

was maintained at Eniwetok Atoll,

At Bikini Atcli a records file of only those

wets

personnel present at the atoll was maintained.

—

~ 39 «

ER mre ne

This split filing system

Select target paragraph3