——_

Laat

Rims)
>

Project 2.51 - Neutron Plux Measurements and Shielding Studies C. We luke

OBJECTIVES
To measure the neutron flux and energy spectrum as e@ fynction of
distance from the point of detonation ot TT: ..

Also to evaluate the angular distribution of the neutron flux aboutRY
evice.

,

:

To compare the foil detector method of deterwining dose in rep
with chemical and semi-conductor methods.

LESTEDENTATI
In order to evaluate the angular ‘istritution of the neutron flux

rorEBT) abot, thre instrument lines vere required.
vere laid as follows:

The lines

Ome line extending along the projection on the

ground of the long axts of the device, one line at 45° to this projection,
and one line st 64° to this srojection.

It was desired that the third line

be placed at 90° to the long axis of the device, however, a permanent
structure along the 90° line required the use of the 64° angle.
Rach instrument line consisted of a 1 inch steel cable laid along
the ground.
placed:

At each 100 yard interval the following detectors vere

Au, 1 az. or 2 on. Blo shielded Puc3?, 238 S, cheeical

dosimeters, cermanium dosimeter, and navy DT60 plese dosimeters.
two samples of Np 237 were available for this shot,

Only

One sample was placed

at the 200 yd. station on the 0° line and one at the 100 yd. atation on

Select target paragraph3