elose-in and long-range--~are of such magnitude and variation that it is
not practical to itemize these in this report. Chemical procedures for

separation and assay of the radioactive isotopes, specialized separation

equipment, counting equipment, and other instruments are included in the

detailed reports by agencies responsible for the separation and assay of
these isotopes; the most pertinent are References 3, 4, 5, 13, 14, 15, 16,
and 17.

2.2

OPERATIONAL PROCEDURES

2.2.1

Close-InSampling.

Close~in gas samples were collected during

Castle at altitudes of 35,000 to 52,000 feet MSL. Sampling aircraft were
directed into the nuclear cloud generally no sooner than two hours sub-

sequent to the detonation and followed each cloud for approximately 5 to
7 hours, obtaining samples. To ensure no cross contamination of sampling
equipment between shots, control samples were taken before and after a

washdown of the sampling equipment.

Gaseous-debris sample sizes collected

varied from 1075 to 10°!’ bomb fraction.

Duration of sample collection

time varied from approximately 40 to 60 minutes in the case of the Squeegee
method to less than 1 minute by the snap~sampling method. Squeegee gas

samples in the high-pressure spheres were removed from the aircraft upon
return to the ground and crated for shipment to the separation laboratories.

Transfer of snap samples from the polyethylene bag to a G-l cylinder was

required prior to shipment.

Representative sections of each test could were sampled, but because
of extreme cloud heights attained, sampling was conducted in only the
lower portions of the cloud for the high-yield detonations.
2.2.2 Long-Range Samples. long-range samples were collected by
WB-29 aircraft steging out of Hickam Field, Guam, and McClellan Air Force
Base (California). Samples were collected from approximately sea level
to 20,000 feet altitude.

Gas samples were obtained with B-3l collection

equipment, which consisted of a Quincy compressor feeding into 5 J~l gas~
storage cylinders. The average sample size collected was approximately

500 ft3.

In addition, these aircraft were equipped with C-1 particulate

samplers employing IPC paper as the filter mediun.

2.3 ANALYTICAL PROCEDURES
223.1

Radiochemical: Particulate.

Particulate nuclear debris col-

lected by the filter-paper technique was radiochemically analyzed in

order to provide the following information:
l. Sufficient fission-product data to establish a fission-yield
Curve with emphasis on studying the trough elements, peak elements, and

those on the right wing of the fission-yield curve.

About 30 fission

Products, from Zn™ through Tb'®!, were chemically separated from the
8ross sample and assayed.
he same sample.
2.

These were then referred to Mo*? measured in

Uranium and plutonium isotopic abundances were determined by

13

Select target paragraph3