19-07.

FRESH VATSR SYSTEMS:

Make connections to fresh water

servicesbrought to a point or points five (5) feet outside

the building line under Section 25 of these specifications.
Run distributing mains with branches to supply all fixtures
and equipment as indicated on the drawings.
‘ater closets,

urinals, and hose bibs will be supplied with salt water;
other fixtures and equipment with fresh water.

19-08,

SALT ‘/JATER SYSTEMS:

all

Make connections to salt water

services prought to a point or points five (5) feet outside

the building line under Section 25 of these svecifications.
Run distributing mains with branches to supply all water closets, urinals, and hose bibbs as indicated on the drawings.
19-09.

HOT WATER SYSTEMS:
a.

Hot water systems are shown for Mess Hall - Sheet

No, 2B-l.00 and Bakery - Sheet No. 28-08; Dentist and Infirmary - Sheet No. 2B-l107; Laundry - Sheet No. 25-09; P. X.,
Barber Shop and Post Office - Sheet No. 2B-li32;

Sheet No, 2h-lL50;

Sheet No, 2n-5419,
b.

Mess Hall -

Mess Hall - Sheet No. 2C-452 and Infirmary -

Infirmary - Sheet No. 28-107.

Hot water for the

Infirmary shall bé suppifedfrom an electric water heater.

tun main with branches from the heater to supply all fixtures
indicated on the drawings.
A return line from the end of the

hot water main shall be run to a hot water circulator, near

the water heater, and from the circulator to the water heater
as shown on the drawings.

ec.

Dentist- Sheet No, 2B-l07.

An electric water

heater shall be located adjacent to the lavatory in the Dentist Office to supply hot water for this lavatory.
dad,
Mess Hall and Bakery;
Laundry.
Hot water for
these buildings shalI be suppifed from steam heated storage
water heaters,
‘lains with branches shall supply all fixtures
and equipment requiring hot water, as indicated on the drawings.
These will be dead-end systems without returns to the
heaters.

2B-.32,

e. P,. X., Barber Shop and Post Office - Sheet No.
Hot water Tor this building Will be supplied from an

electric water heater. A dead-end system will supply fixtures
as indicated on the drawings.

f.

Infirmary - Sheet No. 26-5119.

Hot water for this

building willbe supplied from an oll fired water heater. A
dead-end system will supply fixtures as indicated on the drawings.

19-3