CS-45-48 Douglas Fir Plywood, and shall be EXT-DFPA-

CONCRETE FORM grade not less tnan 5-ply and at least

9/16 inch thick.

3.
Form Lining:
of the following:

(a)

Form linings shall be one.

Plywood:

Plywood for form lining

shall conform to the requirements of the U. 5. Commercial

Standard CS-45-48 Douglas Fir Plywood, and shall be EXTDFPA-CONCRETE FORM grade, 3 ply, not less than 1/4 inch
thick.

(ob)

Fiber-Board:

Fiber-board for form

lining shall conform to the requirements of Federal

Specification LLL-F-311, Class B, not less than 3/16

inch thick.

4,

Metal Forms:

Metal forms shall be of a

type approved by the Engineer that will produce surfaces
equal to those specified for wood forms.

5.
mineral oil.

6.

Form Oil:

Form oil shall be a nomstaining

Form Ties:

Form ties shall be of a design

approved by the Engineer.
Ties shall be adjutable in
length and free of devices which will leave a hole or

depression back of the exposed surface of the concrete

larger than 7/8 inch in diameter.

Ties shall be such

that when forms are removed, no. metal shall be within

one inch of the finished surface.

gHardeners and Dustproofers:
Hardeners and
dustproofing materlal shall be a colorless aqueous
solution of zine or magnesium fluosilicate.
Each
gallon of the solution shall contain not less than 2
pounds of the crystals.
<A proprietary hardener approved
by the Engineer may be used provided the hardener is
delivered ready for use in the manufacturer's original

containers.

h.
Reinforcement Bars:
Reinforcement bars
for concrete shall conform to the requirements of

A.S.T.M. Designation A-15-39.

Types and grades of steel

for specific purposes shall be as specified below"

1.
Tiles and Stirrups:
Ties and Stirrups
shall conform to A.S.T.M. Designation A-15-39 for

billet steel bars, deformed class intermediate grade.