and many had to be replaced during the operation, After Shot 1, several
rafts capsized although they were designed to withstand the effect of 4
10-Hf weapon, 5 miles distant.
3.2.3

Free-flostine Sea Stations

The performance of free-floating buoys as collecting staticns
was important to the main objectives of the present work, Although
little data on fallout were secured from these stations, sufficient
information was obtcined to determine the performance of the equipment
and the suitability of the method. The following observations are
pertinent:
;
(a)
Pexformance of the buoys and associated equipment was
satisfactory, ‘he low-frequency transmitters together with the radio
direction~-finding gear aboard Naval units provided an adequate system
for locatiny and identifying the buoys. The handling problem in placement und recovery raised some difficulties, perticularly in increasing
seas, but was satisfactorily met.

(0)

The free-floating buoy syste. was umsatisfactory for docu-

menting fallout under the conditions of shot scheduling which prevailed
after the first test. This statement would be true of any similar system having the prerequisite that the test take place within a 24-hr
period specified 24 to 248 hr in advance,
3.2.4

Total Collectors

From evidence given in Sections 4.2.1 and 5.1.2, modifications

in the design of total collectors are indicated. Nevertheless, both
devices used made satisfactory collections under same exposure conditions.
As exrected from other experience, the principle of using simple continuously open (collecting) sampling devices was four? setisfactory whenever
only total radiouctivity deposited per unit area was to be determined,
cuch devices are not setisfactory where it is desired to preserve the

charucteristics of the fallout because dilution by extraneous rain and
dust occurs,
362.5

Belt Sampler

The belt sampler was handicapped by too many moving parts which
Were exposed to the elements. It was badly corroded by sea spray; sand
lodged in the gears or under the belt and caused the sampler to function
poorly.

The collection from this sampler on Shot 1 was much better than

on subsequent shots.
in ClLupter 4,

3.2.6

Considerable valuable data were obtained as shown

Liquid Droplet Sampler

The prototypes tested at CASTLE failed to operate in most
instances. This failure was due both to a faulty triggering mechanism
for indexing the trays and to the absence of Jijuid droplets in the
fallout from most shots. Nonetheless this differential collector has

42

Select target paragraph3