..On a fixed schedule prior to the shot, the timing mechanism

in the control room back in Yucca Pass sets in motion the whole

mechanism at the tower, on the ground, and in block houses and
bunkers in the area,

Frequently the most useful measurements are ‘those of what

takes place within the detonation itself,

Since the measurements

must be made in millionths of seconds -- or less--- the resolving

time of equipment must be incredibly short. To catch the immediate early phenomena of the detonation, the detectors and gauges
must be placed on the tower in close proximity to the unit being
tested. This, of course, means that the detectors are almost instantly vaporized, but in the millionths of a second before they
are destroyed, they transmit the all-important signal to the
recording devices in the bunker,
Instrumentation in the bunker consists mostly of power supplies, amplifiers, oscilloscopes, cameras, and other recording
devices. Large coaxial cables carry the signal to the recording
machines from the gauges and indicators outside,
The electronic recording circuits respond extremely rapidly.

Tney can be made to operate in a few hundred-millionths (0, 00000001)

seconds, A great deal of light is required to write on photographic
film in such a limited time. Unless special precautions are taken,
this light would badly fog the film during the many minutes the instrument is waiting for its signal to be given. To solve this
dilemma the electron beam is reduced in intensity and deflected off
the screen prior to zero time. At the last possible instant it is
necessary to raise this intensity to its required value. By an
ingenious arrangement, the coaxial cable is tapped so that the signal itself can trigger an intensifier. The signal, however, passes
through a greater length of cable and hence appears at the scope to
be recorded a micro-second or so after the intensity has been
increased,
The record is of very short duration. Fortunately, however,
the fluorescent oscilloscope screen retains the image briefly after
xhe electron beam has swept across, The persistence of the image,
analagous to a modern television tube where no flicker is discernible to the eye, is sufficient to permit permanent recording
on the photo filn.
Thesm films are the raw data from which the results of the

experiment are interpreted.

After the shot, re-entry to the building and recovery of the
data is made as soon as radiological safety precautions permit.
This is normally within a few hours after the blast.

at!

a

- 35 -

ar

Select target paragraph3