PRIVACYACT MATERIAL REMOVED and Lt. Commande r a, and the recommendations formalizing this request were set forth in a memorandum to biajor Daver on22 December1947. Changes were as follows: Model MX-2 ~ - Reduced quantity from 20 to 10 Mojel MX-6 - - Ordered 20 (New instrument) The model MK-6 was to be manufactured in accordance with the following snecifications: ae Weight: 10 1bs maximun. be Maximum case dimensions: ce Handle: de Case to be metal, heavy enough for field use. 4” x 6" x 10”. hinged, volished unpainted metal or plastic. Surface to be smooth for ease of decontamination; anodized, lacquered or smooth paint finish (no crackel-finish). oe. Case to be water-proof tested under 5 feet of water for two hours. f. Detector component to be an ionization chamber containing sealed air at aporoximately 740 mm mercury pressure at 20° C. _ g The instrument to be tropicalized in accordance with standard Army-Navy specifications. Following were the circuit requirements: a. It must be possible to check the zero setting in a field equal to the maximum radiation measured by the instrument. b. After 60 seconds warm-up period, the zero drift to be less than 5% of full scale per hour on any range. ce | Five ranges of sensitivity were requested: Section IX 17 PRIVACY ACT MATERIAL REMO VED mak