emitters present in the samples were determined from the gamma
curves by use of the method of Conally (1956).

A three-inch by

three-inch NaI (Tl) crystal was used in conjunction with a 256channel analyzer.

Tests for the accuracy of the gamma spectrum

method were made with standards and with radioactive spikes the

disintegration rates of which had been determined from beta

counts.

Accuracy of + 20 per cent, based on known spike mixtures,

was obtained for six of the isotopes (wi85, Co2?, cst37, zr95,
co58 ana C060) present in the samples.

.The lowest limit of de-

tection of any given isotope in the samples was approximately one

per cent of the total gamma activity.

The determinations of the

levels of Rul03_Ryl06 and celt1_c¢elt4 are not as accurate as those
obtained for the other isotopes because of the overlapping gamma
peaks.

The ratio of Rul03 to Rulwas calculated in the following
manner.

The

.624 MEV peak of RyLO6 was determined in selected

samples and the contribution of the
isotope was calculated.

.513 MEV peak from the same

This value was subtracted from the com-

posite .498 MEV gamma peak of Rul93 and the .515 MEV peak of RyLO6
in selected samples,

and the remainder was assumed to be contrib-

uted by RulO3,
The ratio of Cel4l to celt4 was calculated in a similar
way.

The 0.08 MEV and 0.03 MEV peaks of cel44 were determined in

selected samples and the contribution of the

.134 MEV Ce 144

Select target paragraph3