tn 1QFRICIAEGSE ONLY
940406-171827-
set 5 wi
-O001-
1
40-KT and 20-MT weapons required to collapse (a)
selected, underground, reinforced-concrete farch
structures of fixed and two-hinged end conditions,
(b)
801.
KEYWORD(S)
the buried,
and
concrete-arch structures of PLUMBBOB
Project 3.1. The Equivalent Surcharge method, which
assumes failure at the threshold of the compression
regime, appeared to be the most suitable for the design
of structures located above the ground-water table
regardless of the direction of the blast front. For
structures located below the ground-water table, the
Uniform Compression Mode was the most suitable. A method
of predicting radiation transmission for use in the
design of buried structures is given. Procedures and
sample calculations for the design of footings, floor
slabs, and end walls are presented in Appendix A. Sample
calculations for the response of a specific arch under
each of the loading methods are presented in Appendix B.
Appendix C presents results of a study to establish the
ductility factor at the threshold of the compression
regime. 13 references.
HARDTACK/;PLUMBBOB/;UNDERGROUND STRUCTURES/blast
loading ;UNDERGROUND STRUCTURES/design ;REINFORCED
CONCRETE/blast loading ;HARDTACK; PLUMBBOB; PRESSURE
TESTING; DESIGN; CALCULATIONS
Item
45
150.
110.
REPORT NUMBER
PRIMARY TITLE (M)
70.
710.
PERSONAL AUTHOR( M)
CORPORATE SOURCE
(USA)
PUB. DATE (YYMMDD )
CLASSIF. LEVEL T EXT
ABSTRACT
371.
34.
950.
NRDL-TR--152
Investigation and correlation of some physical
parameters of fall-out material
Williamson,
Jr.
San Francisco,
KEYWORD (S)
and density.
What
little correlation that was
possible among accumulated data is presented together
with residual error.
FALLOUT/physical properties ;REDWING/fallout ;TEWA
BURST/fallout ;ZUNI BURST/fallout ;FALLOUT; COLOR;
PARTICLE SIZE;WEIGHT;
DENSITY; SHAPE; REDWING
Item 46
150.
110.
710.
CA
570328
Unclassified
An attempt has been made to correlate some of the
fundamental physical parameters of fall-out material.
Parameters discussed are color and shape, activity, size,
weight,
801.
W.
Naval Radiological Defense Lab.,
REPORT NUMBER
PRIMARY TITLE (M)
CORPORATE SOURCE
DASA--1970
High altitude tests measurement summary
General Electric Co.,
Santa Barbara,
003499
OFFICIAL USE ONLY
CA
(USA).