wenn,
KAUAI, AEC -TRFE
F &SNO.

TITLE

11003
USER

SCIENTIFIC

HRT Tracking Station
STRUCTURE FACILITY NO.

SANDIA

SCIENTIFIC STATION NO.

None

BOD

97-4-59
FoD GO+1 20

FUNDING
AGENCY

AEC

($000)

ENGR

PROC

PRE-GO
Prior Cost
POST -GO

CONST

TOTAL

36.0

«36,0

FURN

TO BE DETERMINED

TOTAL

36.0

36.0

PRIOR YEARS
ENGINEERING

Drawings:

Completed.

F 97-058-S1

F 97-666-Al

JS 97-086C -S1

F 97-058-Sil thru S15
97-3224B-E8

F97-079-W2
F 97-079-W23

JS 97-3224C-A9
JS 97-3224C-Cl2

PROCUREMENT

Completed.

CONSTRUCTION The HRT Tracking facility (completed in 1965) is located at
the northeast end of the trailer park. It consists of two (2) trailers, a roofed
trailer dock,

an amplidyne shelter, and three (3) antennas.

revetment borders the northern side of the facility.

A protective

Geodesic domes enclose

the antennas.

The trailer dock, elevated 4-ft. above grade, is a reinforced concrete slab
b-it. wide by 75-ft. 8-in. long. A wooden stairway is located at its eastern
end, The dock roof, which extends beyond the eastern terminus of the dock,
is 17-ft. high, and 90-ft. long. Steel plate roofing protects the manned dock.
The three (3) antennas spaced on 15-ft. centers, are supported by steel towers
which bear on reinforced concrete piers. The towers are 7 1/2-ft. square in
plan and are 14-ft. high. A plywood platform 10-t* wide and 55-ft. long is
provided at the top of the towers. The platform is enclosed with a 3 1/2-ft.
high wooden handrailing. An 8 x 35-ft. trailer anda 10 x 40-ft. trailer are
located between the trailer dock and the towers.
The amplidyne snelter located in the middle of the tower complex is a7 x 6-ft.
wood-frame,

plywood sided structure,

7

1/2-~ft.

high on a reinforced concrete

slab. Itis lighted and dehumidified. There are two underground runs from
receptacles at the trailer dock each supplying 120/208 volt, 3 phase power to
the amplidyne shelter. Signal cable from the cable termination shelter is laid
in cable trays.
11-1

VOL II

Select target paragraph3